Jump to : Download | Abstract | Keywords | Contact | BibTex reference | EndNote reference |

MSE97

J. Malmivuo, V. Suihko, H. Eskola. Sensitivity distributions of EEG and MEG measurements. IEEE Trans Biomed Eng, 44(3):196-208, 1997.

Download

Download paper: (link)

Copyright notice:This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder.

Abstract

It is generally believed that because the skull has low conductivity to electric current but is transparent to magnetic fields, the measurement sensitivity of the magnetoencephalography (MEG) in the brain region should be more concentrated than that of the electroencephalography (EEG). It is also believed that the information recorded by these techniques is very different. If this were indeed the case, it might be possible to justify the cost of MEG instrumentation which is at least 25 times higher than that of EEG instrumentation. The localization of measurement sensitivity using these techniques was evaluated quantitatively in an inhomogeneous spherical head model using a new concept called half-sensitivity volume (HSV). It is shown that the planar gradiometer has a far smaller HSV than the axial gradiometer. However, using the EEG it is possible to achieve even smaller HSV's than with whole-head planar gradiometer MEG devices. The micro-superconducting quantum interference device (SQUID) MEG device does have HSV's comparable to those of the EEG. The sensitivity distribution of planar gradiometers, however, closely resembles that of dipolar EEG leads and, therefore, the MEG and EEG record the electric activity of the brain in a very similar way

Keywords

[ Anisotropy ] [ Cerebral cortex/anatomy & histology ] [ Electric conductivity ] [ Electrodes ] [ *electroencephalography ] [ Equipment design ] [ Head ] [ Human ] [ *magnetoencephalography/instrumentation ] [ Models ] [ Neurological ] [ Sensitivity and specificity ] [ Skull/anatomy & histology ] [ Support ] [ Non-u.s. gov't ]

Contact

J. Malmivuo
V. Suihko
H. Eskola

BibTex Reference

@article{MSE97,
   Author = {Malmivuo, J. and Suihko, V. and Eskola, H.},
   Title = {Sensitivity distributions of {EEG} and {MEG} measurements},
   Journal = {IEEE Trans Biomed Eng},
   Volume = {44},
   Number = {3},
   Pages = {196--208},
   Year = {1997}
}

EndNote Reference [help]

Get EndNote Reference (.ref)